Fume Capture Arms
A comprehensive review should be performed to gather current and key information – building layout, welding booth and table sizes, work area obstructions, types of welding performed, etc… A wide range of system components are available and it is important to review the work areas to help select the appropriate source capture equipment for the end user.
WXS Series
WXS series arms are available in 7′ to 15′ length and up to 8″ diameter, and can be applied to a wall or ceiling platform for mounting.
WXH Series
WXH series arms have standard lengths of 3′ and 5′, and are supplied with flexible hose and fume receptor.
WXA Series
WXA series arms are available in 2’to 3′ lengths, and articulate in a horizontal path. The arms may be fixed mounted, or may be mounted to a wall or base vertical for up/down sliding and more precise positioning.
WXL Series
WXL series arms are standard in 3′ to 5′ lengths, and 3″ to 4″ diameters, for applications for light fumes or lab fume control. Standard construction is of aluminum, and mounting options include wall, ceiling, and table base.
Fume Hoods
Built of heavy gauge galvanized steel for years of durable service, they are excellent for stationary booths because they require no operator positioning. Standard stock sizes of 3’, 4’, 5’ and 6’ booths with special sizes, materials and configurations also available.
Hood Types Include
- Canopy Hoods
- Slotted Fume Hoods
- Cylindrical Hoods
- Crescent Hood
Exhaust Fans
Belt Drive Fans
Heavy gauge material, close-tolerance running clearances, and rigid manufacturing standards are common to Car-Mon fans. Every fan is individually built and tested here at our factory.
Car-Mon belted fans include variable pitch motor drive which allows for adjustment when actual field conditions are different than design. Belt drive fans are offered in utility set and inline arrangements for convenient choice in appropriate mounting and ducting arrangement.
Each fan shaft is inspected for straightness and proper diameter, and after the fan has passed testing procedures the fan shaft is given an asphaltic coating to protect against corrosion.
Fan vibration and RPM readings are taken on every fan. Vibration is electronically measured at each bearing in both the horizontal and vertical planes. Any fan having an average reading of over 3 mils deflection is not acceptable.
Rest assured that a fan from Car-Mon will provide reliable service for your project needs.
Direct Drive Fans
A critical component of a hazardous fume exhaust system is the exhaust fan. Car-Mon Products, Inc. proudly builds and provides exhaust fans with an extra measure of durability and an uncompromising emphasis on quality. Heavy gauge material, close-tolerance running clearances, and rigid manufacturing standards are common to Car-Mon fans. Every fan is individually built and tested here at our factory.
Direct drive fans are offered in flange mount and base mount arrangements. Flange mount fans can be directly mounted to hose storage reels or wall / ceiling platforms to be used with hose drops or exhaust arms. A common use for our direct drive fans are with a single hose or arm. Typical motor sizes range from 1/3HP to 3HP, and single or three phase multi-voltage industrial grade motors are utilized.
Fan vibration readings are taken on every fan and any fan having an average reading of over 3 mils deflection is not acceptable.
Welding Tables
Designed to handle the everyday wear and tear of parts dragging on and off the table top and the weight load of the parts being welded. Adjustable leveling feet are supplied at each leg for stability and maintaining a level work area. Finished with a durable enamel coating and pre-assembled for easy installation. Custom sizes and configurations can be provided to accommodate your work envelope and booth layout. Please consult the factory or your local Car-Mon representative for engineering and product support.